On this page
A PG packs many people, beds, mattresses, phone chargers and ACs into a building that was usually designed as a house. Many residents sleep behind locked doors, and some do not know the building well. That is why PG fires are dangerous, and why police and municipal inspections increasingly check fire safety first. In 2026, for example, Hyderabad police made extinguishers on every floor and in every room, a second staircase and a hose reel minimum standards for women's hostels and PGs. Most fire safety costs little. This checklist covers what to put in place, room by room.
1. Fire extinguishers
- At least one on every floor, near the staircase, and one in the kitchen. Many local rules now also want one per room in hostels.
- ABC dry powder (multi-purpose) for corridors and rooms. In the kitchen, ABC or a CO₂ extinguisher plus a fire blanket for oil fires.
- Mount them on the wall at hand height, visible, not locked in the office.
- Check the pressure gauge monthly (needle in the green), and get them serviced and refilled by an authorised agency as the label says, usually once a year.
- Show staff how to use one: pull the pin, aim at the base of the fire, squeeze, sweep.
2. Smoke detectors and alarms
- Battery smoke detectors in corridors, the kitchen area (heat detector inside the kitchen itself, to avoid false alarms) and the electrical meter area cost little and wake people at night.
- Test them monthly with the test button. Replace batteries on a fixed date every year.
- Larger PGs and hostels should consider a wired fire alarm panel with manual call points on each floor. Taller buildings usually need one to get a fire NOC.
3. Exits, staircases and grilles
Most deaths in building fires come from smoke and blocked escape, not flames.
- Two ways out from every floor where possible. A second staircase is now required for hostels and PGs in several cities.
- Keep staircases and corridors clear: no bikes, mattresses, luggage, shoe racks or storage.
- No locked grilles on escape routes at night. If the main gate is locked for security, keep the key in a break-glass box next to it, and make sure the night warden is never the only person who can open it.
- Emergency lights or battery lamps on staircases, and glow-in-the-dark exit signs.
- If windows have grilles, consider at least one openable grille per floor.
- Put a simple evacuation plan on the back of each room door: "You are here, nearest staircase, assembly point."
4. Wiring, chargers and AC load
Electrical faults are the most common cause of fires in residential buildings, and PGs run far more devices than the house was wired for.
- Get a licensed electrician to check the load before adding ACs, geysers or more rooms. Old wiring sized for a family overheats with ten ACs.
- Fit MCBs and an RCCB/ELCB in the distribution board, and label which room each MCB controls.
- Enough sockets in each room, so tenants do not chain multi-plugs. Ban heaters, irons and cooking appliances in rooms if your wiring can't take them, and say so in your house rules.
- Replace scorched sockets, loose switches and taped joints at once.
- Keep the meter and DB area dry, clear and free of storage.
- Service ACs before summer; dusty, overloaded units are a fire risk. See our PG maintenance checklist.
5. Kitchen and LPG
- Keep LPG cylinders outside the kitchen where possible, upright, in a ventilated spot, with an ISI-marked regulator and hose. Replace the hose on schedule.
- Commercial kitchens serving many people may need commercial cylinders or a piped connection; follow your gas supplier's rules.
- Fire blanket and extinguisher next to the cooking area. Never use water on an oil fire.
- Clean the exhaust and chimney grease regularly.
- Train the cook to switch off the cylinder valve at night and to know what to do if there's a gas smell: no switches, open windows, valve off, everyone out.
If you serve food, you also need FSSAI registration; see FSSAI for PGs.
6. Rooms and common areas
- No smoking indoors, and no candles or diyas left burning in rooms. Allow lamps only in a supervised common area during festivals.
- Do not store mattresses, cardboard or old furniture under stairs or on terraces near wiring.
- Keep the terrace door openable from inside if the terrace is an escape route.
- Display emergency numbers (112 for emergencies, 101 for the fire service) and the owner's and warden's numbers at reception and on each floor.
7. People: the warden, staff and a drill
- Make one person on duty responsible for fire safety each shift, including nights.
- Brief every new tenant on move-in: where the exits and extinguishers are, the assembly point and the no-heater rule. Our move-in checklist can include it.
- Run a short fire drill twice a year: sound the alarm, everyone out to the assembly point, count heads against your resident list.
- Keep an up-to-date list of who is in the building tonight. In a fire, the first question is "is everyone out?"
8. Fire NOC and paperwork
Whether you need a fire NOC depends on your state's fire rules and on the building's height, floor area and use. Rules usually tighten for buildings above a certain height and for hostels and other residential buildings where many people sleep. The National Building Code of India (Part 4, Fire and Life Safety) is the national reference that state rules build on.
- Ask your state fire service or municipal body whether your building needs a NOC before you start, and plan any upgrades (staircase, alarm, hose reel) into your fit-out.
- Some states also require regular certificates. In Maharashtra, owners file a half-yearly fire-safety certificate (Form B) from a licensed agency.
- Keep extinguisher service records, electrical inspection reports and drill dates in one place for inspections, insurance and any dispute.
- Consider fire insurance for the building contents and your liability; read what it requires (extinguishers, wiring checks) to stay valid.
One-page monthly checklist
| Check | How often |
|---|---|
| Extinguisher gauges in the green, seals intact, all in place | Monthly |
| Smoke detector test button | Monthly |
| Staircases, corridors and exits clear; gate key in its box | Daily (warden) |
| Emergency lights working | Monthly |
| No heaters, multi-plug chains or scorched sockets in rooms | Monthly room check |
| LPG hose, regulator and kitchen exhaust | Monthly |
| Extinguisher service and refill | As labelled, usually yearly |
| Electrical load and wiring inspection | Yearly, and before adding ACs or rooms |
| Fire drill and new-staff training | Twice a year |
Frequently asked questions
How many fire extinguishers does a PG need?
At least one on every floor and one in the kitchen. Some cities now require one in every room for hostels and PGs, so check local rules.
Does a PG need a fire NOC?
It depends on your state's rules and the building's height, area and use. Taller buildings and hostels usually need one. Ask your state fire service or municipality before you start.
Which fire extinguisher is best for a PG?
ABC dry powder extinguishers for rooms and corridors, and a fire blanket plus an ABC or CO₂ extinguisher in the kitchen.
Can I lock the PG gate at night?
For security, yes, but keep the key in a break-glass box next to the gate, and make sure exits are never locked from inside without a quick way to open them.
Last reviewed: November 2026. General safety information, not a substitute for advice from your local fire service or a licensed electrician.